|
|
|
|
|
|
|
|
|
|
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
|
|
|
|
|
|
|
|
|
|
|
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
Designed for use with overhead garage door hardware. Ferrules used to clamp cable loops into fixed position while stops finish off cable ends or act as stopping points at any location on cable. Card contains 2 ferrules and 2 stops.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used on side by side hinge placements for added strength. Factory lubricated, steel inner race with 10 ball bearings. Roller 1-7/8 in OD.
|
Used by most garage door manufacturers. Roller tube accepts a standard 7/16 in OD stem roller. Made of 14 ga galvanized steel, 3 in OAW. Includes four 1/4 in-20 x 1-7/8 in pancake head carriage bolts with nuts.
|
Heavy-duty galvanized steel pulley with galvanized steel strap. Case hardened steel race with steel ball bearings. Factory lubricated and can be used at stationary or spring pulley positions. The width of the groove measures 5/16 in from inside wall to inside.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used by most garage door manufacturers. Roller tube accepts a standard 7/16 in OD stem roller. Made of 14 ga galvanized steel, 3 in OAW. Includes four 1/4 in-20 x 1-7/8 in pancake head carriage bolts with nuts.
|
Replaces most handles currently in use. Galvanized steel construction. Use vertically or horizontally. Includes two 1/4 in - 20 x 1-7/8 in pancake head carriage bolts with nuts.
|
Factory lubricated, steel inner race. Fits 2 in standard J-track. Roller 1-7/8 in OD.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used by most garage door manufacturers. Roller tube accepts a standard 7/16 in OD stem roller. Made of 14 ga galvanized steel, 3 in OAW. Includes four 1/4 in-20 x 1-7/8 in pancake head carriage bolts with nuts.
|
Short stem heavy-duty roller with steel inner race, 10 ball bearings. Includes 2 roller assemblies. Roller 1-7/8 in OD.
|
Galvanized carbon steel aircraft cable used on 7 ft H torsion spring doors.
|
|
|
|
|
|
|
|
|
|
|
|
|
Galvanized carbon steel aircraft cables used on extension spring doors. 1/8 in replaces most wood doors, 3/32 in replaces most fiberglass and aluminum doors.
|
Heavy-duty galvanized steel, spring-loaded slide-bolt lock with latch bolt release lever for overhead garage doors. Used with GD-52147 outside lock and latch assembly.
|
Works only from inside for extra protection as a night or vacation security lock. Fits most garage doors. Engages slot in vertical track. 7/8 in W x 1/8 in thick steel slide bolt with heavy-duty galvanized steel housing. Includes lock assembly and four 1/4 in-20 x 1-7/8 in pancake-head carriage bolts with nuts.
|
|
|
|
|
|
|
|
|
|
|
|
|
Heavy-duty galvanized steel pulley with galvanized steel strap case hardened steel race with steel ball bearings factory lubricated can be used at stationary or spring pulley positions. The width of the groove measures 5/16 in from inside wall to inside.
|
Zinc die-cast construction, keyed lock, 5/16 in square shaft, 4-5/8 in long, 1-1/2 in hole centers, replaces many garage door, camper and R.V locking handles. Screws attach to lock from the inside of door. Contains 1 locking handle, 2 keys.
|
Heavy-duty galvanized steel fixture with adjustable roller plate, accepts a standard 7/16 in Dia stem roller, used on most wood doors.
|
|
|
|
|
|
|
|
|
|
|
|
|
5/16 in square shaft, 3 in L, replaces most garage door, camper and RV locking handles. Zinc die-cast construction. 1-1/2 in hole centers. Includes locking handle and 2 chrome-plated solid brass keys.
|
Prime-Line Door T Handle, Die-Cast Zinc, Zinc Plated, Includes: (1) Die Cast Outside Handle with 5/16 in Square X 3 in Length Shaft, (1) Die Cast Zinc Inside Handle with Set Screws
|
Heavy-duty (10, 000 cycles) extension springs have double loop ends for extra durability. 5 sizes will replace most all spring configurations on residential doors that are no higher than 7 ft. 1/8 in galvanized carbon steel aircraft cable.
|
|
|
|
|
|
|
|
|
|
|
|
|
Heavy-duty (10, 000 cycles) extension springs have double loop ends for extra durability. 5 sizes will replace most all spring configurations on residential doors that are no higher than 7 ft. 1/8 in galvanized carbon steel aircraft cable.
|
Heavy-duty (10, 000 cycles) extension springs have double loop ends for extra durability. 5 sizes will replace most all spring configurations on residential doors that are no higher than 7 ft. 1/8 in galvanized carbon steel aircraft cable.
|
Painted die-cast inside lock with heavy-duty steel spring bolt, key cylinder has aluminum face and 5-pin tumbler lock with cylinder ring, will replace most locking mechanisms of this type.
|
|
|
|
|
|
|
|
|
|
|
|
|
Includes 8 ft chain/cable assembly, rope, master link kit and 2 rail clips.
|
Most doors, in recent years, have been supplied with torsion springs that is located directly above the door and mounted to the header. Replacement will require the use of 2 winding rods (GD-52238) and a clear understanding of wire size and handing.
|
Most doors, in recent years, have been supplied with torsion springs that is located directly above the door and mounted to the header. Replacement will require the use of 2 winding rods (GD-52238) and a clear understanding of wire size and handing.
|
|